<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-17 03-58-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 58 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.0 kHz 61 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 62 kHz 18522 0,8962
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 4,37 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 3:58, 17.08.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 62 kHz MIN: 10 kHz % above 76 kHz: 0,8962 Acquired: 2025/08/17 3.56.59 Total samples: 18522 Equivalent time: 0:15:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,4 dBr MIN: 1,0 dBr AVE: 4,37 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2025/08/17 3.56.59) 03.44 03.46 03.48 03.50 03.52 03.54 03.56 0 2 4 6 Pm [dBr]